ISO 286
Fits Calculator
Calculates limit deviations and clearance/interference for hole-basis fits per ISO 286-1. Select an ISO preferred fit or enter a custom tolerance code.
Nominal diameter
Select fit
H7/k6TRANSITION
Hole — H7
Upper dev
+21 µm
Lower dev
+0 µm
Max size
25.0210 mm
Min size
25.0000 mm
Shaft — k6
Upper dev
+15 µm
Lower dev
+2 µm
Max size
25.0150 mm
Min size
25.0020 mm
Max clearance
19 µm
Max interference
15 µm
ISO 286-1:2010. Values for reference only — verify against the current standard for production use.